The COOL Vapour Compression Cycle (VCC) system, from CP Cases, is a portable air conditioning unit designed to provide a convenient way to deliver high level, efficient air cooling in remote locations and meet the demands of defence and civil operations in extreme environments.

  • Robust construction
  • Easy to operate
  • Low maintenance
  • Highly efficient
  • Automatically adjusts to high demand
    • Installed within CP Cases' established Amazon chassis, COOL VCC is robust, easy to set up and use and enhances the operating effectiveness of the equipment it is used in conjunction with.

      Installed within CP Cases' established Amazon chassis, COOL VCC is robust, easy to set up and use and enhances the operating effectiveness of the equipment it is used in conjunction with.

      The COOL VCC system consists of an evaporator section that provides cool air into the case, a vapour compression unit and a condenser section where the heat from the case is expelled from the unit.

      The condenser section has two fans that extract the heated air out of, and away from, the condenser section. Initially, both fans will operate at low speed; however, if the temperature, and therefore, system pressure, rises to a sufficient level, the fans will automatically step up into their higher gear to operate at optimum speed.

In the most hostile conditions

Reliable, functional, operational


This feature enables a reduction in external noise unless full power is required, for example, at extreme temperature, but can be manually over-ridden if required.

The condenser section has two fans that extract the heated air out of, and away from, the condenser section. Initially, both fans will operate at low speed; however, if the temperature, and therefore, system pressure, rises to a sufficient level, the fans will automatically step up into their higher gear to operate at optimum speed.

Removing the end cover, during the set-up of the system, will expose the condenser section, or heat rejection component, of the case and the drain vent can be accessed. Any water that collects during the operation of COOL VCC, from the cold side of the system will drain out of the cooling collar and be extracted from the system via this vent.

Downloads

COOLPAC flyer PDF

Available from CP Cases UK Office: +44 (0)20 8819 3432

Unit 11, Worton Hall Industrial Est., Worton Road, Isleworth, Middlesex TW7 6ER

Email: chill@coolportableairconditioning.com  |  www.coolportableairconditioning.com